Author: Bachmann, J.E.
Paper Title Page
WEC1C1 Improvement Design of a Beam Current Monitor Based on a Passive Cavity Under Heavy Heat Load and Radiation 205
 
  • P.-A. Duperrex, J.E. Bachmann, M. Rohrer, J.L. Sun
    PSI, Villigen PSI, Switzerland
 
  The High Intensity Proton Accelerator at PSI delivers a continuous proton beam of up to 2.4 mA with a maximum energy of 590 MeV to two meson production targets, M and E, and then to the spallation target. Eight meters downstream from the target E located a beam current monitor MHC5, which endure intensive scattered particles from Target E and cause large temperature variation, further induce operation and calibration problems. To address these issues, a graphite monitor was designed to replace the older aluminum one. Based on years of operation experiences of this graphite cavity, improvement design has been also considered, including beam positon pickups refinement, on-line calibration methods implementation, as well as manipulation maintenance issues. Detailed aspects of the performance of the monitor and its improvement design will be presented in this paper.  
slides icon Slides WEC1C1 [4.024 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-HB2023-WEC1C1  
About • Received ※ 01 October 2023 — Revised ※ 04 October 2023 — Accepted ※ 09 October 2023 — Issued ※ 16 October 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)